- Amperage Rating :20 A
- Color :White
- Manufacturer Name :Leviton
- NEMA Rating :NEMA 5-20R
- Number of Poles :2
- Number of Wires :3
Leviton® SmartlockPro® GFCI Receptacle, Duplex Feed-Through Self-Test Slim Tamper-Resistant Weather-Resistant, 125 VAC, 20 A, 1 hp, 2 Pole, 3 Wires, NEMA 5-20R NEMA Rating, Commercial/Residential/Specification Grade, -35 to 66 deg C, Back/Side Wire Terminal, Polycarbonate, White, 4.21 in H x 1.69 in W x 1.4 in D Dimensions.
Peace of mind, all the time. The SmartlockPro® self test GFCI tests itself even if you forget. Designed to meet the latest UL standard for auto-monitoring (self test) our complete line of self test GFCIs periodically conduct an automatic internal test to confirm that it can respond to a ground fault. With the slimmest profile ON the market, the device allows for fast and easy installation, while Leviton® patented reset lockout mechanism prevents reset of the GFCI if it is not wired or operating correctly. The SmartlockPro® self test GFCI is the smart choice in ground fault circuit interrupter protection.
The Leviton GFWT2-W is a 20A, 125VAC SmartlockPro self-test GFCI receptacle designed for tamper-resistant and weather-resistant applications. It is suitable for residential, commercial, and specification-grade installations where GFCI protection, 20A feed-through capability, and a white duplex receptacle format are required.
- Leviton® SmartlockPro® GFWT2-W Duplex Feed-Through Self-Test Slim Tamper-Resistant Weather-Resistant GFCI Receptacle With White Test, Reset Button, 125 VAC, 20 A, 2 Poles, 3 Wires, White
Self-test GFCI operation → Periodically tests internal GFCI electronics to confirm protected power is available.
SmartlockPro reset lockout → Prevents reset if the device is miswired, not powered, or unable to pass its internal test.
Weather-resistant construction → Designed for damp or wet locations when installed with the required wet-location cover or outlet box hood.
Tamper-resistant duplex receptacle → Provides a 20A GFCI outlet configuration for locations requiring tamper-resistant protection.
20A feed-through rating → Can provide GFCI protection to properly connected load-side receptacles.
Slim profile design → Takes up less space in the wall box, helping simplify installation in standard or shallow electrical boxes.
Back and side wire terminals → Supports flexible wiring options for installation.
Status indicator light → Provides visual feedback for normal operation, trip condition, or replacement/service attention.
Specification
Details
Manufacturer
Leviton
Manufacturer Part Number
GFWT2-W
Product Series
SmartlockPro®
Product Type
Self-Test GFCI Receptacle
Receptacle Configuration
Duplex
Outlet Type
Tamper-Resistant (TR), Weather-Resistant (WR)
Voltage Rating
125 VAC
Amperage Rating
20 A
Frequency
60 Hz
Feed-Through Rating
20 A
Horsepower Rating
1 hp
NEMA Configuration
NEMA 5-20R
Number of Poles
2
Number of Wires
3
Wiring Method
Back Wire / Side Wire
Material
Polycarbonate
Color
White
Grade
Commercial, Residential, Specification Grade
Operating Temperature
-35°C to 66°C (-31°F to 151°F)
Height
4.21 in
Width
1.69 in
Depth
1.40 in
Self-Test Function
Yes
Status Indicator Light
Green/Red LED
Weather Resistant
Yes
Tamper Resistant
Yes
Reset Lockout Feature
Yes
Standards & Certifications
UL 943 Class A (GFCI), UL 498, CSA C22.2 No. 144.1 (GFCI), CSA C22.2 No. 42 (Outlets)
Compatible Conductors
Copper or Copper-Clad Wire Only
Wire Compatibility
Not for Use with Aluminum Wire
Warranty
Limited 2-Year Warranty
Kitchens requiring GFCI protection
Bathrooms requiring GFCI protection
Laundry rooms requiring GFCI protection
Workshops requiring GFCI protection
Basements requiring GFCI protection
Garages or carports requiring GFCI protection
Pool areas requiring GFCI protection
Damp or wet locations where a weather-resistant GFCI receptacle is required and the correct wet-location cover or outlet box hood is used
Compatible with copper or copper-clad wiring only.
Not for use with aluminum wire.
Supports LINE-only wiring or LINE and LOAD wiring when downstream receptacle protection is required.
LOAD terminals must only be used for wiring receptacles that require GFCI protection from this device.
For wet locations, the receptacle must be protected by a suitable cover plate or outlet box hood that keeps the receptacle and plug face dry.
Do not install on circuits that power life support equipment.
Must be installed according to national and local electrical codes.
What is the Leviton GFWT2-W?
The Leviton GFWT2-W is a 20A, 125VAC SmartlockPro self-test GFCI receptacle with tamper-resistant and weather-resistant construction. It uses a white duplex NEMA 5-20R configuration and is rated for 20A feed-through protection.
Does this GFCI receptacle test itself?
Yes. The self-test function periodically checks the GFCI electronics to confirm that protected power is available. The status indicator light shows normal operation, trip condition, or potential replacement/service attention.
Can this receptacle protect other outlets downstream?
Yes. When connected correctly using the LOAD terminals, this GFCI receptacle can provide protection to load-side receptacles. The LINE and LOAD connections must be identified and wired correctly.
Can the Leviton GFWT2-W be used in wet or damp locations?
Yes. It is weather resistant and designed for damp or wet locations. For wet locations, it must be installed with a suitable cover plate or outlet box hood that keeps the receptacle and plug face dry.
What type of wire can be used with this GFCI receptacle?
This receptacle is for use with copper or copper-clad wire only. It must not be used with aluminum wire.